{"id":760,"date":"2022-11-15T15:00:00","date_gmt":"2022-11-15T14:00:00","guid":{"rendered":"https:\/\/pilz-magazine.com\/de\/?p=760"},"modified":"2024-09-11T10:41:03","modified_gmt":"2024-09-11T08:41:03","slug":"managing-access","status":"publish","type":"post","link":"https:\/\/pilz-magazine.com\/en\/managing-access\/","title":{"rendered":"Managing access"},"content":{"rendered":"\n<p>The reading unit PITreader from Pilz is just this type of flex\u00adible system with which access to plant and machinery can be clearly con\u00adtrolled. The machine oper\u00ada\u00adtors carry their indi\u00advidual per\u00admis\u00adsion on a key in this case and use this to autho\u00adrise them\u00adselves at the reading unit PITreader. The fact that this is based on a com\u00adplex per\u00admis\u00adsion matrix or spec\u00adi\u00adfi\u00adca\u00adtions reg\u00adu\u00adlated across the com\u00adpany is not apparent when you look at the small key.<\/p>\n\n\n\n<p>So how do the data get onto the key? The user uses the inte\u00adgrated PITreader web server to easily pro\u00adgram the asso\u00adci\u00adated PITreader key \u00adtransponder key and stores the user data and per\u00admis\u00adsions on it. All impor\u00adtant set\u00adtings are made directly at the PITreader, which speeds up \u00adcom\u00admis\u00adsioning, including the con\u00adfig\u00adu\u00adra\u00adtion of inter\u00adfaces.<\/p>\n\n\n\n<p>After set\u00adting up the keys, man\u00adage\u00adment now plays the impor\u00adtant role of main\u00adtaining the per\u00admis\u00adsions and keeping them updated. The PIT Transponder Man\u00adager (PTM) is avail\u00adable to help with this task: On the graph\u00adical inter\u00adface, the admin\u00adis\u00adtrator \u00adman\u00adages their PITreader key user set\u00adtings, block lists and user data. With pre-con\u00adfig\u00adured tem\u00adplates, indi\u00advidual user per\u00admis\u00adsions are written to the PITreader key in just a few steps. The import func\u00adtion allows infor\u00adma\u00adtion to be quickly read directly into the inte\u00adgrated data\u00adbase.<\/p>\n\n\n\n<p>If sev\u00aderal reading units PITreader are in use at a com\u00adpany, these devices are organ\u00adised using the User Authen\u00adti\u00adca\u00adtion Ser\u00advice (UAS). It enables the con\u00adnec\u00adtion of man\u00adage\u00adment sys\u00adtems such as the PTM or a dif\u00adferent user man\u00adage\u00adment soft\u00adware in the com\u00adpany with PITreader. UAS has a cen\u00adtral autho\u00adri\u00adsa\u00adtion data\u00adbase for users, thereby enabling the import and assign\u00adment of data from the PTM or even the dis\u00adtri\u00adb\u00adu\u00adtion of block lists to all PITreaders. Admin\u00adis\u00adtra\u00adtors can view the cur\u00adrent status of all PITreaders and dis\u00adplay a diag\u00adnostic list. In this way, a quick overview is also pos\u00adsible with the use of sev\u00aderal PITreaders. <\/p>\n\n\n\n<p class=\"link-pilz\">Whether indi\u00advidual machines or a machine park used world\u00adwide: with these dig\u00adital tools, an effi\u00adcient access and per\u00admis\u00adsion system based on PITreader can be easily imple\u00admented and \u00adman\u00adaged.<\/p>\n\n\n\n<div class=\"wp-block-group link-pilz is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"link-pilz\"><a href=\"https:\/\/www.pilz.com\/en-INT\/products\/operating-and-monitoring\/control-and-signal-devices\/pitmode-operating-mode-selector-switch\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.pilz.com\/en-INT\/products\/operating-and-monitoring\/control-and-signal-devices\/pitmode-operating-mode-selector-switch<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>A mod\u00adular system offering that pre\u00advents unau\u00adtho\u00adrised access and can be \u00adadapted to the respec\u00adtive appli\u00adca\u00adtion is impor\u00adtant because of how indi\u00advidual \u00adaccess to plant and machinery is. The most effort is in the main\u00adte\u00adnance of \u00adper\u00admis\u00adsions and this can be sup\u00adported by the appro\u00adpriate soft\u00adware tools.<\/p>\n","protected":false},"author":27,"featured_media":1147,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"wp_typography_post_enhancements_disabled":false,"footnotes":""},"categories":[19,7,1,11],"tags":[],"class_list":["post-760","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industrial-security","category-issue-3-2022","category-pilz-magazine","category-trends"],"acf":[],"_links":{"self":[{"href":"https:\/\/pilz-magazine.com\/en\/wp-json\/wp\/v2\/posts\/760","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pilz-magazine.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pilz-magazine.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pilz-magazine.com\/en\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/pilz-magazine.com\/en\/wp-json\/wp\/v2\/comments?post=760"}],"version-history":[{"count":5,"href":"https:\/\/pilz-magazine.com\/en\/wp-json\/wp\/v2\/posts\/760\/revisions"}],"predecessor-version":[{"id":1674,"href":"https:\/\/pilz-magazine.com\/en\/wp-json\/wp\/v2\/posts\/760\/revisions\/1674"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pilz-magazine.com\/en\/wp-json\/wp\/v2\/media\/1147"}],"wp:attachment":[{"href":"https:\/\/pilz-magazine.com\/en\/wp-json\/wp\/v2\/media?parent=760"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pilz-magazine.com\/en\/wp-json\/wp\/v2\/categories?post=760"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pilz-magazine.com\/en\/wp-json\/wp\/v2\/tags?post=760"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}